A1 Non-Combustible Calcium Silicate Fire Board — Ceilings, Ducts and Partitions

A1 non-combustible calcium silicate board is used where an interior assembly must not add fuel to a fire: ceilings, duct enclosures, partitions, risers and fire doors. Mingfa's GF-1100 board is classified A1 to EN 13501-1 and is supplied with the density, thickness and batch data needed for system testing.

A1 Non-Combustible
1100°C Grade
Export Documentation

What "A1 Non-Combustible" Means

EN 13501-1 classifies construction products by reaction to fire. Class A1 is the highest level: the product does not contribute to fire at any stage, including the fully developed fire, and produces no smoke or flaming droplets that would be attributed to it. A1 products are tested to EN ISO 1182 for non-combustibility and EN ISO 1716 for gross calorific potential.

A1 is often confused with a fire-resistance rating. The two answer different questions. A1 describes how the material behaves when exposed to fire — whether it adds fuel, smoke or droplets. EI 30, EI 60, EI 120 and EIS ratings describe a complete assembly and how long it resists fire, smoke and temperature rise. A board can be A1 and still fail an EI test if the frame, fixings, joints or seals are wrong. A board can also pass an EI test as part of a system without being the only A1 component.

This is why a fire specification should name both: the reaction-to-fire class of the board (A1 to EN 13501-1) and the system test evidence for the wall, ceiling, duct or door (EN 1364, EN 1366, EN 1634 or the local equivalent). See the standards comparison for the difference between product standards and fire classification.

Product Grades for Interior Fire Protection

Mingfa's GF-1100 fireproof board is a dense calcium silicate board with a dry density of 350–450 kg/m³, a maximum service temperature of 1100°C and A1 classification to EN 13501-1. It is asbestos-free and dimensionally stable under heat. For applications that need higher density or screw retention, the same material is available in higher grades up to 900 kg/m³.

PropertyGF-1100 valueRelevance to interior fire protection
Density (dry)350–450 kg/m³Mass for acoustic and fire performance; manageable weight for ceilings and partitions
Compressive strength≥2 MPaResists handling and point loads during installation
Flexural strength≥1.5 MPaHandles transport and fixing without cracking
Thermal conductivity~0.09 W/m·K at 200°C; ~0.14 W/m·K at 600°CAdds thermal resistance to the assembly; not a substitute for insulation design
Maximum service temperature1100°CSurvives fire exposure without losing structural integrity
Fire classificationA1 to EN 13501-1; A1 to GB 8624Non-combustible; no contribution to fire, smoke or flaming droplets
Asbestos content0%No asbestos exposure risk in cutting or installation
Thickness range9–40 mm for interior fire applicationsSelected with the system test, not by a stand-alone board rating

For ceilings and partitions, 9–15 mm boards are common; duct enclosures often use 20–40 mm; fire door cores use 30–60 mm. These are starting ranges, not a substitute for the tested system. The board thickness, density, framing, fixings and joint treatment must match the test report for the assembly.

Ceilings: Fire-Rated Membranes with Acoustic Options

A fire-rated ceiling is a membrane that protects the structure above or separates a room from the floor above. Calcium silicate board contributes non-combustibility, dimensional stability and mass. The fire resistance of the ceiling depends on the board thickness, the framing, the cavity and the fixings, tested as a system to EN 1364-2 or the local standard.

Fire performance. For a ceiling membrane, the board is fixed to a metal grid or timber frame with the specified screw pattern and joint detail. EI 30, EI 60 and EI 120 ceilings use different board thicknesses and framing; the tested detail should be followed exactly, including the perimeter and penetration seals.

Acoustic performance. A ceiling can be specified for sound absorption or sound insulation. Absorption is measured by NRC (ASTM C423 or ISO 354); insulation is measured by Rw or STC (ISO 10140-2 and EN ISO 717-1, or ASTM E90 and E413). A bare calcium silicate board is reflective and absorbs little; perforated acoustic panels with a fleece or mineral-wool backing and an air cavity reach NRC 0.70–0.90. A fire-rated ceiling that also needs acoustic insulation depends on mass, airtightness and the cavity — not on the board alone. See the acoustic performance section for the test basis.

Where it fits. Plant rooms, service corridors, hospitals, schools, hotels, laboratories and commercial kitchens often need both a fire-rated ceiling and acoustic control. The board is also used as a protection layer above service voids and as a lining in risers and shafts.

Ducts and Service Shafts: EIS Ratings and Smoke Leakage

Fire-rated duct enclosures protect steel ducts or form self-supporting shafts. Calcium silicate boards are used as the outer fire protection layer around the duct or as the shaft lining. The relevant European tests are EN 1366-1 (vertical and horizontal ducts), EN 1366-8 (smoke extraction ducts) and EN 1366-9 (smoke extraction ducts in single fire compartments).

EIS, not just EI. Duct systems are usually specified for integrity, insulation and smoke leakage — EIS. The smoke-leakage criterion is why joint sealing and support spacing matter as much as board thickness. A 40 mm board in one tested EIS 120 system is not interchangeable with a 25 mm board from another system. The tested detail includes the board, the fixings, the joints, the duct supports and the penetration seals.

Board thickness. Fire-rated duct enclosures commonly use 20–40 mm calcium silicate board. The thickness is selected from the system test report for the required EIS period. Ribs, supports and joint strips are part of the system; omitting them can invalidate the rating.

Cold ducts. Calcium silicate is not a vapour barrier. If the duct operates below the dew point, use a closed-cell insulation or a sealed vapour barrier; the calcium silicate board handles fire protection, not condensation control.

Partitions, Risers and Compartmentation

Interior partitions and risers use calcium silicate board as a non-combustible layer on a steel or timber frame. The assembly is tested to EN 1364-1 for partitions and EN 1364-2 for ceilings, or to the local fire test standard.

For EI 60 and EI 120 partitions, the tested detail usually uses one or two layers of board on each side, with staggered joints and mineral wool in the cavity. The board thickness, stud spacing, fixing pattern and joint treatment are part of the system. A single layer of 12 mm board on one side is not a substitute for a tested two-layer system, even if the product is A1.

Risers and service shafts need the same discipline at penetrations. Cables, pipes and ducts passing through the shaft require tested penetration seals; the board alone does not close the opening. Access hatches must also match the tested detail, including their fire rating and fixing.

For fire door cores, the board is the core inside a steel or timber leaf. The door assembly must be tested to EN 1634-1 for fire and, where required, to ISO 10140-2 / EN ISO 717-1 for acoustics. See the fireproof door core range and the door-core acoustic section for the assembly logic.

Acoustic Performance: Absorption vs Insulation

Interior fire boards are often asked to control noise as well as fire. The two acoustic metrics should not be mixed: NRC describes absorption at a surface; Rw and STC describe how much sound an assembly blocks.

A bare calcium silicate board is a dense, reflective surface. Manufacturer data for standard calcium silicate ceiling tiles sit around NRC 0.50; perforated acoustic panels with a fleece or mineral-wool backing and an air cavity reach NRC 0.70–0.90. Those values describe finished acoustic panels, not an unperforated fire board.

Sound insulation is a system property. Published data for a calcium silicate partition system on 70 mm steel studs at 600 mm centres with 60 mm stone wool reach Rw 43 dB. The board alone has no Rw. For doors, core-only claims around ≥30 dB are common, while a complete door with a drop seal has been published at Rw 38 dB. Seals, thresholds, glazing and frame gaps can change the result more than a board upgrade.

If the project needs both fire and acoustic performance, specify a system that has been tested for both. Do not perforate an A1 fire board on site and assume the fire rating is unchanged; perforations and acoustic backings must be part of the tested fire assembly.

Moisture, Fixing and Interior-Only Use

Calcium silicate board is dimensionally stable but it absorbs water. It is intended for protected interior and industrial service, not for weather-exposed facades. This distinction matters when the project mixes interior fire protection with exterior cladding.

Keep it dry. Store boards flat and dry; seal cut edges where the specification requires it; do not install into standing water or wet cavities. In humid or wet areas, the board must be protected by the finish system and the cavity must be ventilated.

External cladding is a different product. Weather-exposed sheathing boards used behind rainscreens, render or brick slips are typically calcium silicate cement or fibre-cement products engineered for external exposure. Mingfa's industrial calcium silicate fire board is not a substitute for those products. If the project needs an external sheathing board, specify a purpose-made sheathing product with its own system test evidence and weather approval.

Fixing. Use the screw type and spacing from the tested system. Stagger joints, keep the specified expansion gaps, and do not replace the specified fixings with shorter or lighter screws. For ceilings, the grid and hangers are part of the system; for partitions, the studs and cavity fill are part of the system.

Finishing. Joints are usually filled and taped with the system's joint compound, or covered by the specified finish. Paint, render or decorative finishes must be compatible with the board and must not compromise the fire classification. For wet areas, use the specified waterproofing system over the board.

Specification Checklist and Test Evidence

A fire specification for interior calcium silicate board should answer five questions. If any answer is missing, the submittal is not complete.

1. What is the reaction-to-fire class? State A1 to EN 13501-1 (or the local equivalent) and provide the classification report. A1 is a material property; it is not an EI rating.

2. What is the fire-resistance requirement? State EI 30/60/120 or EIS 90/120 and provide the system test report for the exact wall, ceiling, duct or door build-up. The report should name the board thickness, density, framing, fixings and seals.

3. What is the product standard? Name ASTM C533, EN 14306 or GB/T 10699 and the grade or type. For a C533 product, state the type and density; for an EN 14306 product, state the declared product characteristics.

4. What acoustic performance is required? If Rw/STC is required, specify the assembly and the test standard. If NRC is required, specify the finished acoustic panel and backing, not the bare board.

5. What is the service environment? Interior dry, humid, wet, or protected industrial. Calcium silicate is not a weather-exposed facade board; if the environment is external, select a purpose-made sheathing product and its system.

A1 vs A2 vs B — Reaction-to-Fire Classes

EN 13501-1 groups construction products into classes A1, A2, B, C, D, E and F. The class reflects the product's contribution to fire growth, smoke and flaming droplets under the standard test suite. A1 is the top class; F is the lowest.

ClassContribution to fireTypical test basisWhere it is specified
A1No contribution; non-combustibleEN ISO 1182 and EN ISO 1716Protected escape routes, high-rise, fire-rated assemblies, specifications that require non-combustible components
A2Limited contribution; satisfies the non-combustibility test with a limited calorific contributionEN 13823 (SBI) plus EN ISO 1182/1716Where A2 is accepted as an alternative to A1
B–EIncreasing contribution to fire growthEN 13823 and/or EN ISO 11925-2Where the fire strategy allows a lower class
FNo performance determined—Not acceptable where a reaction-to-fire class is required

A1 is often specified for ceilings, ducts and partitions in protected escape routes, hospitals, schools and high-rise buildings. The specification should state the class and the test standard; a supplier's statement that the board is "non-combustible" is not the same as a classification report. Ask for the EN 13501-1 classification document and confirm the product name on the report matches the product being supplied.

Installation Details That Decide the Rating

A fire-rated assembly fails at the details. The board may be A1 and the system may have a test report, but a missing screw, an unfilled joint or an unsealed penetration can open a path for fire and smoke.

Fixings. Use the screw type, length and spacing from the tested system. Screws must penetrate the framing by the specified amount; too short a screw leaves the board loose, and too long a screw can damage the frame or the board. Do not substitute drywall screws for the specified fire-rated screws without the system owner's approval.

Joints. Stagger joints between layers and between adjacent boards. Fill and tape joints with the specified compound, or use the specified joint strip. A continuous vertical joint through both layers is a direct path for heat and smoke.

Penetrations. Pipes, cables, ducts and supports that pass through the board need tested penetration seals. The seal must match the penetration type, size and substrate; a generic mastic is not a substitute for a tested firestop system.

Perimeter and movement joints. Leave the specified gap at the perimeter and at movement joints, and seal it with the specified fire-rated sealant. Packing the gap with rigid material can transfer movement into the board and crack it.

Double layers. Where the system uses two layers, offset the joints of the second layer from the first. The second layer should not repeat the first layer's joint pattern; the offset is part of the fire performance.

Submittal Package for a Fire-Rated Assembly

A complete submittal connects the product, the system test and the installation detail. The reviewer should be able to check each link without asking for another document.

ItemDocumentWhat to check
BoardProduct data sheet and EN 13501-1 A1 classification reportProduct name, density, thickness, A1 class, report date
SystemEN 1364 or EN 1366 test report for the wall, ceiling or ductBoard thickness, framing, fixings, joints, seals and rating
InstallationSystem owner's installation manual or detail drawingsScrew spacing, joint treatment, penetration details, perimeter seals
PenetrationsFirestop test reports and data sheetsCompatibility with the board, penetration type and rating
QualityBatch test data and ISO 9001 certificateDensity, strength, moisture, batch traceability

The submittal should also identify the party responsible for the system design and the installation. A board supplier can provide material data, but the system test and the installation detail belong to the system owner and the contractor. Clear responsibility is part of a reliable fire strategy.

Frequently Asked Questions

Is A1 non-combustible the same as fire-rated?

No. A1 is a reaction-to-fire classification: the board does not contribute fuel, smoke or flaming droplets. A fire rating (EI or EIS) describes a complete tested assembly and how long it resists fire. A1 is necessary for many systems but does not replace the system test.

Can calcium silicate board be used for ceilings?

Yes, in protected interior ceilings. The ceiling is tested to EN 1364-2 or the local standard, with the specified board thickness, framing, fixings and joints. For acoustic ceilings, use a tested acoustic panel with the required NRC; a bare fire board is reflective.

Can calcium silicate board be used for fire-rated ducts?

Yes, as part of a tested duct enclosure or shaft lining. Duct systems are tested to EN 1366-1, EN 1366-8 or EN 1366-9 for EIS performance, including smoke leakage. The board thickness, supports, joints and penetration seals must match the system report.

What thickness do I need for EI 60 or EI 120?

There is no single thickness that applies to every assembly. A tested EI 60 or EI 120 partition, ceiling or duct uses a specific board thickness, number of layers, framing and joint detail. The thickness must come from the system test report for that build-up, not from a generic table.

Does the board provide acoustic insulation?

The board contributes mass and airtightness, but the Rw or STC rating belongs to the complete assembly. A bare board is reflective; NRC values of 0.50–0.90 apply to finished acoustic panels with perforations and backing. For a partition or door, specify the tested system's Rw or STC.

Can the board be used on an external facade?

No. Industrial calcium silicate fire board absorbs water and is intended for protected interior or industrial service. Weather-exposed sheathing behind rainscreens, render or brick slips is a different product — typically a calcium silicate cement or fibre-cement sheathing board with its own system tests and weather approval.

What is the difference between A1 and A2?

A1 is the highest reaction-to-fire class and does not contribute to fire. A2 is a lower class that permits a limited contribution. For many interior fire assemblies, A1 is specified; the project's fire strategy should state the required class and the test report should confirm it.

Is the board waterproof?

No. It tolerates occasional moisture better than some fibrous insulations but is not waterproof. Keep it dry before installation, seal cut edges where specified, and protect it with the finish system. For wet areas, use the project's waterproofing detail.

What standards apply to the board?

Mingfa's board is produced to GB/T 10699 and tested against the property requirements used by ASTM C533 and EN 14306. Fire classification is A1 to EN 13501-1 and A1 to GB 8624. See the ASTM C533 guide and technical certifications for the document list.

Can Mingfa support a system test?

We supply the board with consistent density, thickness and fire performance, plus batch data for the test programme. The system test is carried out by the ceiling, duct, partition or door manufacturer with its frame, fixings and seals. We can provide material samples and documentation for that work.

Request an A1 Fire Board Quotation

Tell us the application — ceiling, duct, partition, riser or fire door — the required EI or EIS period, the board thickness in the tested system and the quantity. We will confirm the grade, density, A1 classification report and packing.

Get a Quote Email Inquiry

Include the system test reference and required thickness for the fastest review.